Used with a pull handle outside, inside handle or handle and pull: door can be opened by pushing or pulling when the electrical control is on (e.g. timer, reader, push button). Inside handle opens the lock always.
-
Ideal for entrance doors, corridor doors, high traffic exit doors and access-controlled doors. Can be used on doors with door automatics
-
Deadbolt is withdrawn by motor and thrown by spring force
-
Deadbolt and anti-friction bolt are both deadlocked when door closes
-
Anti-friction bolt is freed when deadbolt withdrawn by motor
-
Easily reversible trigger bolt for all hands of door
-
In the event of power failure deadbolt is automatically thrown, released by mechanical override
-
Meets EN179 and EN1125 for emergency and panic exit doors and EN1634-1 for fire resistance (when used with correct exit hardware)
-
Tested to draft standards for burglary prEN1627 and mechanical resistance EN12209 Control switches
-
Continuous – bolt remains in open position as long as circuit is closed
-
Momentary – bolt deadlocks after a delay of 2-15 secs (adjustable)
-
Monitoring for Request to Exit, Bolt position, Door position and Cylinder operation
NOTE Please add 10mm to the case depth to allow for cable socket and plug